摘要

采用ThermoFlex软件建立了200 MW级整体煤气化联合循环(integrated gasification combined cycle,IGCC)系统模型,从系统的角度出发计算研究了200 MW级IGCC系统的变工况特性。详细讨论了燃气轮机负荷、大气环境条件和整体空分系数对系统性能的影响。结果表明,燃气轮机采用压气机进口可转导叶角度调节–等燃气透平初温的调节方式降负荷时,燃气透平排气温度先增加后降低,而系统效率先缓慢降低后快速降低。随大气温度增加,燃气轮机功率、汽轮机功率和系统净功率均下降。在大气温度不变的条件下,大气压力对燃气轮机效率和系统净效率基本没有影响。增加整体空分系数可提高系统净效率,却使系统净功率降低。

关键词 整体煤气化联合循环   变工况特性   燃气轮机负荷   整体空分系数   大气环境条件  
Research on Off-design Characteristics of Integrated Gasification Combined Cycle System
CHEN Xiao-li1, WU Shao-hua1, LI Zhen-zhong2, PANG Ke-liang2, WANG Yang2, CHEN Lei3, HE Xiang3, WANG Jing3
1. School of Energy Science and Engineering, Harbin Institute of Technology
2. National Power Plant Combustion Research Center
3. Department of Power Engineering, University of Shanghai for Science and Technology
Abstract:

The model of 200 MW integrated gasification combined cycle (IGCC) system was established by the software ThermoFlex. The off-design characteristics of 200 MW IGCC system were studied from the point of system and effects of gas turbine’s load, atmosphere circumstance condition and air separation unit (ASU) integrated coefficient (Xas) on characteristics of system were fully discussed. Results show that while in regulation manner of adjusting compressor inlet guide vanes (IGV) angle and keeping turbine inlet temperature (T3) constant to reduce gas turbine’s load, the variety trend of gas turbine exhaust temperature is firstly increased and then declined. System efficiency firstly declines slowly and then declines quickly as gas turbine’s load reducing. Gas turbine power, steam power and system net power all decline as atmosphere temperature increasing. Atmosphere pressure almost has no effect on gas turbine efficiency and system net efficiency when atmosphere temperature is fixed. Increasing Xas can enhance system net efficiency and reduce system net power.

Keywords: integrated gasification combined cycle   offdesign characteristic   gas turbines load   air separation unit integrated coefficient   atmosphere circumstance condition  
收稿日期 2008-07-16 修回日期  网络版发布日期 2009-05-22 
DOI:
基金项目:

国家863高技术基金项目(2006AA05A110, 2007AA05Z247)。

通讯作者: 陈晓利
作者简介:
作者Email:

参考文献:
本刊中的类似文章
1.杨承 杨泽亮 蔡睿贤.基于全工况性能的冷热电联产系统效率指标比较[J]. 中国电机工程学报, 2008,28(2): 8-13
2.陈晓利 吴少华 李振中 庞克亮 王阳 王颖.整体煤气化联合循环发电系统中气化参数对气化单元性能的影响[J]. 中国电机工程学报, 2009,29(23): 1-6
3.王颖 邱朋华 吴少华 李振中 王阳 庞克亮 陈雷 陈晓利.整体煤气化联合循环系统气化岛特性模拟研究[J]. 中国电机工程学报, 2010,30(2): 35-39
4.王颖 邱朋华 吴少华 李振中 王阳 庞克亮 陈雷 陈晓利.整体煤气化联合循环系统中废热锅炉特性研究[J]. 中国电机工程学报, 2010,30(5): 54-58
5.乌晓江 张忠孝 周托 陈玉爽 朴桂林 小林信介 森滋勝 板谷義紀.煤焦–CO2/H2O气化反应过程中灰的熔融特性[J]. 中国电机工程学报, 2010,30(14): 36-43
6.邱朋华 王文杰 焦广亮 吴少华 秦裕琨.CO对碱金属凝结特性影响的试验研究[J]. 中国电机工程学报, 2010,30(11): 56-61

Copyright by 中国电机工程学报